PROJECT-CONFIGURED BOOSTER SYSTEM

YHXW Box-Type Non-Negative Pressure Water Supply Equipment

YHXW combines a hygienic buffer water chamber and a variable-frequency boosting skid in one compact box-type unit. Connected directly to the municipal network, it adds pressure on top of residual mains pressure while the buffer volume smooths peak demand.

01Water sourceMunicipal water main
02Control conceptVFD constant pressure
03Hydraulic dutySelected per project
04MediumPotable / clean water
YHXW Box-Type Non-Negative Pressure Water Supply Equipment
YHXW packaged water supply equipment · final configuration follows the approved duty schedule

WORKING PRINCIPLE

From inlet conditions to stable building pressure.

The controller reads the outlet pressure continuously and adjusts pump speed and staging to the actual demand.

Clean tank / inlet main→Pressure sensing→VFD pump set→Outlet sensing→Building supply
01

Water enters the hygienic buffer chamber from the municipal connection.

02

Inlet and outlet pressure are monitored as demand changes.

03

The VFD pump skid adds the required pressure and smooths peak demand.

04

The controller protects the municipal interface while supplying the building network.

SELECTION DATA

Confirm these values before quotation.

Share the values you know. Our engineering team can identify the gaps before the final model, pump duty and interface schedule are issued.

Design / peak flowm³/h; include diversity and future allowance
Target outlet pressureMPa or mH₂O at the building manifold
Buffer chamber volumeConfirm useful volume and peak-demand profile
Pump arrangementNumber of pumps, duty/standby and motor power
Municipal connectionInlet pressure, pipe diameter and available interface
Site inputsPower supply, access, noise limits and delivery route

SYSTEM COMPONENTS

01

Variable-frequency pump set

Duty/standby arrangement and motor power follow the approved hydraulic schedule.

02

Pressure transducer

Outlet feedback gives the controller the signal required for constant-pressure operation.

03

VFD / PLC / HMI

Automatic staging, soft start, fault alarms and manual backup control.

04

Manifold and valves

Factory-assembled suction/discharge pipework simplifies the pump room interface.

05

Protection package

Overload, short circuit, phase loss, overheat and over/under-voltage protection.

06

Optional communications

IoT/4G remote status and alarm reporting can be included when required.

TYPICAL APPLICATIONS

Where stable water pressure is needed.

For building and site water-supply projects, with the booster arrangement selected around demand, inlet conditions and the required pressure setpoint.

Daily domestic demand

Residential communities

Configured around the required flow, head and pressure setpoint.

Continuous occupancy

Hotels and public buildings

Configured around the required flow, head and pressure setpoint.

Variable process demand

Schools and hospitals

Configured around the required flow, head and pressure setpoint.

Remote network pressure

Network-end pressure support

Configured around the required flow, head and pressure setpoint.

Request booster system selection

Share the hydraulic values you know. Enter “Please advise” where the project still needs engineering review.